Table of burner and nozzle specifications
Supply pressure
Nominal (mbar)
Minimal (mbar)
Maximised (mbar)
28-30
20
35
37
25
45
20
17
25
C. Rapid
B. Semi-rapid
A. Auxiliary
D. Triple ring
100
75
55
130
3.00
1.65
1.00
3.25
0.70
0.40
0.40
1.30
40
30
30
57
86
64
50
91
218
120
73
236
214
118
71
232
116
96
71
124
286
157
95
309
Table 1
Liquid gas
Natural gas
Burner Diameter
(mm)
Heating
power
kW (H.s.*)
By-pass
1/100
(mm)
Nozzle
1/100
(mm)
G30Nomin. G31
Flow rate *
g/h
Nozzle
1/100
(mm)
G20
Flow rate *
l/h
Reduc.
* At 15°C and 1013 mbar - dry gas
** Propane P.C.S. = 50.37 MJ/kg
*** Butane P.C.S. = 49.47 MJ/kg
Natural P.C.S. = 37.78 MJ/m